Computer-aided detection in screening mammography
an increase in the biopsy rate by 19.7%
- tech
- cad-mammography
- passes the definition as
- classifiers fit to annotated mammogram databases to mark suspicious regions for the radiologist
- from
- 1998
- region
- US
- domain
- health
- side
- loss
- people
- 429,345 screening mammograms (2007)
- effect
- 19.7 percent (2007) — increase in the biopsy rate — women sent for tissue sampling they would not otherwise have had
- reversible
- yes
- who holds the switch
- owner:radiology practices
- attribution
- named
- source kind
- secondary
- the statistic
- Fenton et al. (NEJM 2007), over 429,345 mammograms, found specificity fell from 90.2% to 87.2%, positive predictive value from 4.1% to 3.2%, and the biopsy rate rose 19.7% where CAD was used.
- source
- https://pmc.ncbi.nlm.nih.gov/articles/PMC3085409/
- proposed by
- researcher (opus), brief 2026-09-06, era-1990-2011
- received
- 2026-09-06T09:39:39-04:00
- harvest report
- impacts/harvest/2026-09-06-era-1990-2011.md
Rulings, in order
- 2026-09-06T09:39:47-04:00 · validatorpass — quote found on the fetched page (exact match; HTTP 200 text/html; charset=utf-8)
- 2026-09-06T09:59:36-04:00 · sessionseverity — an unneeded biopsy: reversible harm
The proposal as it arrived (JSON)
{
"id": "p2026-09-06-039",
"received": "2026-09-06T09:39:39-04:00",
"proposer": "researcher (opus), brief 2026-09-06, era-1990-2011",
"kind": "entry",
"sha": "7dcb9f6f3ccc53ca",
"data": {
"kind": "entry",
"tech": "cad-mammography",
"tech_name": "Computer-aided detection in screening mammography",
"definition": "classifiers fit to annotated mammogram databases to mark suspicious regions for the radiologist",
"from": "1998",
"region": "US",
"domain": "health",
"side": "loss",
"people": {
"n": 429345,
"unit": "screening mammograms",
"date": "2007"
},
"effect": {
"n": 19.7,
"unit": "percent",
"date": "2007",
"what": "increase in the biopsy rate — women sent for tissue sampling they would not otherwise have had"
},
"reversible": true,
"switch": "owner:radiology practices",
"statistic": "Fenton et al. (NEJM 2007), over 429,345 mammograms, found specificity fell from 90.2% to 87.2%, positive predictive value from 4.1% to 3.2%, and the biopsy rate rose 19.7% where CAD was used.",
"source": "https://pmc.ncbi.nlm.nih.gov/articles/PMC3085409/",
"quote": "an increase in the biopsy rate by 19.7%",
"attribution": "named",
"source_kind": "secondary"
},
"from_file": "impacts/harvest/2026-09-06-era-1990-2011.md"
}